1DESTINY 4100Installation InstructionsK1106 3/98Downloaded from - http://www.guardianalarms.net

Seite 2

10Wiring Diagram+ 5 VDCMicrophone 1 SignalShieldShieldMicrophone 2 SignalMicrophone 3 SignalProgramPhoneStatusPOWERJ5Mic Inputs+123ComSiren2-WayRedGre

Seite 3

11The Destiny-4100 is compatible with the ADEMCO 4140-BLK removable terminal strips. Ifnecessary, these connectors allow for quick replacement of th

Seite 4 - Software Revisions

12System TerminalsHouse Phones: The R1 and T1 terminals provide telephone service to the house if the installationcontains an RJ-31X terminal block fo

Seite 5 - Table of Contents

13Battery Leads: Connect the red lead to the + battery terminal and the black lead to the - batteryterminal. The battery is tested every 180 seconds

Seite 6 - Specifications

14POWER LED: At the top right of the board is a red LED labeled "POWER" which is illuminated when thesystem is receiving power.STATUS LED: A

Seite 7

15Two Resistor Supervision: This wiring arrangement allows the system to detect and handle open loops and shorts asa trouble condition. Through progr

Seite 8

16ProgrammingSystem options are contained in EEPROM. Each programmable section of memory has a 4 digit location and a threedigit value. To reduce th

Seite 9 - Mounting the Control Board

17Quick StartKeypad connection: Connect a hardwire keypad to the keypad terminals on the control board, be certain toproperly match the colors as foll

Seite 10 - Wiring Diagram

18Using This Manual:Automated Locations: Automated Location prompt for specific information and automatically record theappropriate information into t

Seite 11 - Wiring Notes

19System SetupZone 1-8System KeypadsSystem Board Inputs 1-8Local Phone PanicTwo Wire Smoke LoopWireless TransmittersZone 9Zone 27Zones 24 - 25Zones 10

Seite 13

20Programming ZonesThe device types for each zone on the Destiny 4100 are predefined. The device assignments are fixed and may notbe modified.Zones

Seite 14

21Zone 1 Zone 2Input Control Board Loop 1 Input Control Board Loop 2Option Location Default New Value Option Location Default New ValueZone Type 0647

Seite 15

22Zone 9Input 2-Wire SmokeOption Location Default New Value Default DescriptionZone Type 0775 255 Word 1 Word 2 Word 3 Word 4Option 1 0771 016 Smoke (

Seite 16 - Exiting Program Mode

23Zone 10 Zone 11Input Transmitter 1 Serial #: Input Transmitter 2 Serial #:Option Location Default New Value Option Location Default New ValueDevice

Seite 17 - Quick Start

24Zones 18 - 23: Alarm Type Transmitters ContinuedZone 18 Zone 19Input Transmitter 9 Serial #: Input Transmitter 10 Serial #:Option Location Default N

Seite 18 - Using This Manual:

25Portable TransmittersType Description Value5801...4 button portable...

Seite 19 - System Setup

26Zone 28Input Remote PhoneOption Location Default New Value Default DescriptionZone Type 1079 255 Word 1 Word 2 Word 3 Word 4Option 1 1075 000 Remote

Seite 20 - Zone Options 2

27Zone 29: Monitor Trouble ConditionsOption - A description of each option is available in the Glossary Location Value* Duration for recognition of A

Seite 21

28Automated Programming LocationsPlace system in RF field strength mode and speak serial number...

Seite 22 - 5816 (MN) 5817

29VocabularyWord LocationAccess...024Account...025Alarm...222Alert...026Am.

Seite 23

3Dear Dealer/Installer:We appreciate your decision to use the Destiny 4100 for this installation. As a division of the Pittway Corporation andmember

Seite 24

30User Code 1 2 3 4 5 6 7 8Location 0065 0066 0067 0068 0069 0070 0071 0072System Times And Other OptionsSystem Time Options - A description of each t

Seite 25

31System Options - Group 1Options - Enter Total - A description of each option is available in the Glossary Location ValueDisarm before rearm...

Seite 26 - Zone 27: Local Phone

32Monitor Trouble ConditionsOption - A description of each option is available in the Glossary Location Value* Monitor low battery and enable battery

Seite 27 - System Access Codes

33System TriggersEvent Location Output Location Option Location Time Option Default TimesAny alarm activation...012

Seite 28 - Assigning Words to Zones

34System Triggers OptionOption - Enter Total ValueActivation ActionDo Nothing...

Seite 29 - Vocabulary

35Automated Event Memory Log UploadChoose upload days total Location ValueSunday...

Seite 30 - User Code Options

36Fail To Open (Disarm) / Fail to Close (Arm)Options - Enter Total Location ValueEnable Fail to Open...

Seite 31

37Two-Way Digit Assignments This feature is not permitted in a UL installationTelephone Digit Default Function Location Default Value0 Exit

Seite 32 - Bypass Options

38Ademco Contact ID Report CodesAPEX Description Code Sent to Central Station ADEMCO DescriptionExterior instant...E131

Seite 33 - System Triggers

39Dialer OptionsOptions - Enter total ValueDial Phone #1...

Seite 34 - System Triggers Option

4Software RevisionsCurrent software at time of printing:Control Panel: 1.00Bridge (Gate): 1.02EXP-8: 1.01RK36 LED Keypad: 4.01Panel Software Revision

Seite 35

40Report Type Location ValueOpen (Disarm) Central Station Report Code...0359...011________Dialer Option...

Seite 36 - Reporting Format

41Glossary of TermsAccess code before arm: In this configuration, a full access code (arm/disarm code) must be entered to arm thesystem. Once armed,

Seite 37 - Two-Way Voice Options

42Button Functions: These are activations that are controlled by portable transmitters and/or keycombinations on keypads.Silence Day Zone: Cancels a

Seite 38

43Bypass Mode: To bypass individual zones, enter a valid full function code followed by the 9 digit. Thesystem will speak "BYPASSED MODE, ENTER Z

Seite 39 - Report Codes

44Clear Keypad Status: Under very unusual circumstances, a keypad may not receive a transmission from thecontrol panel resulting in a status message n

Seite 40

45Display Open at Keypad: Used to show when specified zones are open. Typically, all internal zones (PIR's, SmokeDetectors) are not programmed t

Seite 41 - Glossary of Terms

46Enable Two-way Callback: For this option to be used, at least one activation must be programmed to enable two-way voice/listen-in with the central s

Seite 42

47There are two different levels or types of extended monitor, A and B. Locations 0177and 0175 determine which zone types are to be monitored by each

Seite 43

48No Exterior Instant When enabled, this option will eliminate the exit delay on all exterior instant zonesExit Delay: following arming to either HOME

Seite 44

49Report Code: All events that initiate a communicator report are associated with a report code (basedon zone type) that appears at the central statio

Seite 45

5Specifications...6Items

Seite 46

50Set Time and Date: After entering 9991 the system will prompt "Enter Eleven." The time, day, and date areentered in the following format

Seite 47

51Speak Phone Number: To confirm programmed phone numbers, Enter the appropriate 9000 location and thenumber will be spoken. Special dialing feature c

Seite 48

52Touch Tone / Pulse: This location determines the type phone service the panel uses for dialing. Program 000for touch-tone or 001 for rotary.Track A

Seite 49

53Disarm: Active when the panel is disarmed. The output is restored when the panel isarmed.Access Code Entered: Output is activated when an access

Seite 50

54code is entered or the two-way callback time expires. If neither code option is selected,the system will be in listen-in mode when the phone is ans

Seite 51

55Day: When the system is not armed a Day zone will cause an Extended Monitoractivation and can send a Day Zone Trouble report to the central station

Seite 52

56Silent Panic: Silent panic zones respond by activating the communicator. An activationappears in system status, however, no audible indication is

Seite 53

57This equipment has been tested to FCC requirements and has been found acceptable for use. The FCC requires thefollowing statement for your informati

Seite 54

58Preparation of an evacuation plan Is of prime importance in fireprevention. Establish a household emergency evacuation plan in theevent of fire. Re

Seite 55

59WARNINGTHE LIMITATIONS OF THIS ALARM SYSTEMWhile this System is an advanced wireless security system, it does not offer guaranteed protection agains

Seite 56

6SpecificationsElectrical: Voltage Input: 16.5 VAC 40 VA from supplied transformerExternal Speaker: 10 Watt minimum, 8Ω horn type - Ademco 713 or equi

Seite 57

60ADEMCO LIMITED WARRANTYAlarm Device Manufacturing Company, a Division Of Pittway Corporation, and its divisions, subsidiaries and affiliates(`Seller

Seite 58

7Speaker Output: 10 Watt internal siren driver with full speech10 Watt external siren driver with full speechDesigned for use with 8Ω, 10 watt minimum

Seite 59

8Items Included With the Control Panel:Please examine the contents of the shipping box for the following items:1 - Control Panel 1 - Lock, key, and re

Seite 60 - ADEMCO LIMITED WARRANTY

9Retainer Clip(Note Position)Retainer SlotLockedUnlockedControl BoardControl Board1. Remove the cabinet door2. Remove the lock knockout from the contr